CIP cleaning circuits
Circulating caustic, acid and rinse water between production batches. The pump must handle caustic soda, nitric acid and hot water in sequence, and run against changing back-pressure. It must also tolerate short dry-run phases when tanks empty.
What the circuit demands of the pump
Temperatures cycle from ambient to 85 °C. The pump sees thermal cycling on every run.
The return pump often runs on an emptying tank. Dry-run protection is needed.
How Vestera equips the circuit
VX 200 magnetic-drive pump
Stainless steel 1.4408 with a ceramic containment shell. No shaft seal to wear in caustic service.
VC-6 controller
Dry-run detection stops the pump when the tank runs empty, and restarts it on level.
VK control valves
Pneumatic actuators switch the supply and return lines.
Typical circuit layout
Supply pump
Tank to plant.
Return pump
Plant to tank. Dry-run exposed.
Dosing of concentrate
VK valve, small VX 200 size.
Heat exchanger loop
Hot water, 85 °C.
Engineering notes
Material selection +
1.4408 handles caustic soda and nitric acid up to the concentrations typical in CIP. PP is not used here.
Dry-run behaviour +
On loss of level, the VC-6 stops the pump. It restarts the pump when level returns.
Documentation +
The machine builder receives documentation per serial number.